4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
Altogen Biosystems(授权代理)
主营:主营:高分子化学,分子和细胞生物学,转染试剂
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > Cell_transfection > Altogen/MIA PaCa-2转染试剂盒(胰腺癌)/1.5 ml CRISPR/2174
商品详细Altogen/MIA PaCa-2转染试剂盒(胰腺癌)/1.5 ml CRISPR/2174
Altogen/MIA PaCa-2转染试剂盒(胰腺癌)/1.5 ml CRISPR/2174
Altogen/MIA PaCa-2转染试剂盒(胰腺癌)/1.5 ml CRISPR/2174
商品编号: 2174
品牌: Altogen Biosystems
市场价: ¥13920.00
美元价: 8352.00
产地: 美国(厂家直采)
公司:
产品分类: 细胞转染
公司分类: Cell_transfection
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍

Description

Product Availability: In Stock (delivery within 2-3 business days, no extra charge for drop-shipping).

Ordering: To place an order via credit card or PO use Add to Cart button (creating an account is not required).


Transfection Reagent for MIA PaCa-2 Cells (Pancreatic Carcinoma Cells, CRL-1420)

  • Proprietary cationic lipids formulation
  • High transfection efficiency of small RNA (siRNA, shRNA, miRNA), mRNA, pDNA
  • Effective and robust intracellular delivery
  • Work in the presence of serum
  • Optimized transfection protocols are adapted for use with both standard & reverse transfection methods
  • Download in vitro MiaPaCa2 transfection protocol: [PDF]
  • Download MiaPaCa2 CRISPR/Cas9 transfection protocol: [PDF]
  • Download PowerPoint presentation for Mia-PaCa-2 cells transfection kit: [PPT]
  • Developed and manufactured by Altogen Biosystems

Transfection Efficiency:

Reagent exhibits at least 88% transfection efficiency of siRNA delivery. Transfection efficiency was determined by qRT-PCR.

Transfection Protocol and MSDS:

Download Altogen Biosystems MiaPaCa-2 Transfection Protocol: [PDF]

Download MSDS: [PDF]

MIA PaCa-2 Cell Line:

Pancreatic adenocarcinoma is an aggressive malignancy that is often advanced at the time of initial diagnosis due to the lack of early symptoms and reliable screening tests as well as rapid progression of the disease. Established cell lines have proven to be a useful tool for investigating the epidemiology of pancreatic cancer.  The MIA PaCa-2 cell line was initially isolated by A. Yunis et al. in 1975 using pancreatic tumor cells of a 65-year-old Caucasian male with pancreatic carcinoma. The tumor was negative for an alkaline phosphatase stain and did not express high amounts of carcinoembryonic antigen. This is a hypotriploid cell line with floating rounded cells that display epithelial morphology. MIA PaCa-2 cells produce plasminogen activator and human colony-stimulating factor (CSF-1). The modal chromosome number for this cell line is 61, and a few normal chromosomes are absent. MIA PaCa-2 has a doubling time of roughly 40 hours and is an excellent host for biomedical research related to pancreatic cancer. Altogen Biosystems provides lipid-based transfection reagent kits for the MIA PaCa-2 cell line.

Data:

MIA PaCa2 Transfection Reagent

Figure 1. Cyclophilin B silencing efficiency was determined by qRT-PCR in the MIA Paca-2 cells transfected by Cyclophilin B siRNA or non-silencing siRNA control following the recommended transfection protocol. Cyclophilin mRNA expression levels were measured 48 hours post-transfection. 18S rRNA levels were used to normalize the Cyclophilin B data. Values are normalized to untreated sample. Data are presented as means ± SD (n=6).

MIA-PaCa2-cells-transfection-protocol

Figure 2. Protein expression of Cyclophilin B in MIA PaCa-2 cells. DNA plasmid expressing Cyclophilin B or siRNA targeting Cyclophilin B were transfected into MIA PaCa-2 cells following Altogen Biosystems transfection protocol. At 72 hours post-transfection the cells were analyzed by Western Blot for protein expression levels (normalized by total protein, 10 µg of total protein loaded per each well). Untreated cells used as a negative control.

Request a Quote for
MIA PaCa-2 Transfection Kit

Altogen Biosystems:
Altogen Biosystems manufacturers preoptimized transfection kits for cancer research. Reagents and transfection protocols are optimized for individual cancer cell lines. Altogen Biosystems developed two types of in vivo delivery kits for animal research: Tissue-targeted reagents (delivery into liver, pancreas, and kidney tissues), and in vivo biodistribution reagents (PEG-Liposome, Nanoparticle, Lipid, and Polymer-based kits). Optimized transfection protocols provide efficient intracellular delivery of proteins, DNA, and RNA molecules in vitro and in vivo. Read more about transfection technology at Altogen’s Transfection Resource.

Altogen Research Services:

Altogen Labs provides GLP-compliant contract research studies for pre-clinical research, IND applications, and drug development. Biology CRO services include: Xenograft models (30+), development of stable cell lines, ELISA assay development, cell-based and tissue targeted RNAi studies, safety pharm/tox assays, and other studies (visit AltogenLabs.com).

Volume Options:

  • 0.5 ml (Catalog #6850)
  • 1.5 ml (Catalog #6851)
  • 1.5 ml CRISPR (Catalog #2174)
  • 8.0 ml (Catalog #7064)
品牌介绍
Altogen Biosystems全国代理部分产品列表: 货号 产品 规格 价格(美元) 5030       1703 A204 Transfection Reagent (Rhabdomyosarcoma) 0.5ml 170 1704 A204 Transfection Reagent (Rhabdomyosarcoma) 1.5ml 348 窗体顶端 窗体底端   2101 A204 Transfection Reagent (Rhabdomyosarcoma) 1.5ml CRISPR 548 窗体顶端 窗体底端   7018 A204 Transfection Reagent (Rhabdomyosarcoma) 8.0ml 1044 窗体顶端 窗体底端   1167 A375 Cells Transfection Reagent (CRL-1619) 0.5ml 195 1168 A375 Cells Transfection Reagent (CRL-1620) 1.5ml 427 2102 A375 Cells Transfection Reagent (CRL-1621) 1.5ml CRISPR 627 1169 A375 Cells Transfection Reagent (CRL-1622) 8.0ml 1281 5030 Nanoparticle In Vivo Transfection Reagent 0.5 ml - 10 injections  445 5010 LIPID In Vivo Transfection Reagent 0.5 ml - 10 injections 405 5040 PEG-Liposome In Vivo Transfection Reagent 0.5 ml - 10 injections 465 5020 POLYMER In Vivo Transfection Reagent 0.5 ml - 10 injections 425 5050 Pancreas In Vivo Transfection Kit 0.5 ml - 10 injections  495 5060 Liver In Vivo Transfection Kit 0.5 ml - 10 injections  495 5070 Kidney In Vivo Transfection Kit 0.5 ml - 10 injections  495 1721 BMS2 Transfection Reagent (Bone Marrow Cells) 0.5 ml  231 6345 C6 Transfection Reagent (Glioma Cells, CCL-107) 0.5 ml  199 6803 DLD-1 Transfection Reagent (Colon Cancer, CCL-221) 0.5 ml  201 1775 HUH-7 Transfection Reagent (Liver Cancer Cells) 0.5 ml  179